Kardia
Units I-II
Megalopolis
B
Unit IV
16
Reduction of particulate emissions: High performance electrostatic precipitators installed in 1991
Reduction of SO2 emissions: wet gas desulphurisation system in operation in Unit IV since
1999; modernisation of the desulphurisation units under way.
Reduction of NOx emissions: Low excess air, air staging, flue gas recirculation.
Reduction of particulate emissions: High performance electrostatic precipitators in operation
since 1993
Reduction of SO2 emissions: natural desulphurisation
Kardia
Units III-IV
Modernisation of the cooling towers planned
Reduction of particulate emissions: High performance electrostatic precipitators in operation
since 2003 and 2004 respectively
Reduction of SO2 emissions: natural desulphurisation
Modernisation of steam turbines completed
Ptolemaida
Units I-III
Modernisation of the cooling towers completed
Reduction of particulate emissions: High performance electrostatic precipitators in operation
since 1987
Reduction of SO2 emissions: natural desulphurisation
Modernisation of the cooling towers completed
Ag. Dimitrios
Units I, III, IV
Ptolemaid
a
Unit IV
Upgrading of the boiler in Unit II
Reduction of particulate emissions: High performance electrostatic precipitators in operation
since 1994
Reduction of SO2 emissions: natural desulphurisation
Modernisation of the cooling towers completed
Reduction of particulate emissions: Upgrading of existing and installation of new electrostatic
precipitators to be completed by 2007-2008
Reduction of SO2 emissions: natural desulphurisation
Reduction of NOx emissions: Low excess air, air staging, flue gas recirculation.
Modernisation of cooling towers in units I-IV planned for 2008
Ag. Dimitrios
Unit II
Modernisation of steam turbines and of preheating system for condensates planned for 2008
Reduction of particulate emissions: High performance electrostatic precipitators in operation
since May 2006; modernisation of existing and introduction of new precipitators should be
completed by late 2007
Reduction of SO2 emissions: natural desulphurisation
Reduction of NOx emissions: Low excess air, air staging, flue gas recirculation.
Melitis
Ag. Dimitrios
Unit V
Modernisation of steam turbines and of preheating system for condensates planned for 2008
Reduction of particulate emissions: High performance electrostatic precipitators in operation
since 1999
Reduction of SO2 emissions: natural desulphurisation
Reduction of NOx emissions: Low excess air, air staging, flue gas recirculation.
Reduction of particulate emissions: High performance electrostatic precipitators operate in
conjunction with a wet gas desulphurisation system
Reduction of SO2 emissions: A wet gas desulphurisation system in operation
Amynteon I-II
Reduction of NOx emissions: Low excess air, air staging, flue gas recirculation.
Reduction of particulate emissions: High performance electrostatic precipitators in operation in
Units 1 and II
Reduction of SO2 emissions: natural desulphurisation
Reduction of NOx emissions: Low excess air, air staging, flue gas recirculation.
Modernisation of the cooling towers completed